Dameng database startup report code =-803 [Invalid ini config value] error
Description of error phenomenon: after archiving is enabled for Dameng database configuration, the restart service cannot be restarted normally, and the log error message is as follows:
The database startup log prompts are as follows:
2020-04-17 11 dmserver startup failed 3515 FATAL [FATAL] database P0000014440 T00000000000014880 dmserver startup failed, code =-803 [Invalid ini config value]
2020-04-17 11 nsvr_ini_file_read failed 3515 FATAL [FATAL] database P0000014440 T00000000000014880 nsvr_ini_file_read failed, [code:-803]
Treatment method:
Comment out the ARCH_WAIT_APPLY parameter in the archive parameter file generated after configuring the archive log, or change the value of this parameter to 0 or 1, and then restart the service to start normally.
Attached: configuration information of Dameng archived parameter file
# DaMeng Database Archive Configuration file
# this is comments
# ARCH_WAIT_APPLY = 255
[ARCHIVE_LOCAL1]
ARCH_TYPE = LOCAL
ARCH_DEST = E:\ dmdbms\ data\ arc
ARCH_FILE_SIZE = 128,
ARCH_SPACE_LIMIT = 0