Dameng database startup report code =-803 [Invalid ini config value] error

Shulou Source: shulou.com Published: 2022-06-01 05:48:38 09月10日 Update

Description of error phenomenon: after archiving is enabled for Dameng database configuration, the restart service cannot be restarted normally, and the log error message is as follows:

The database startup log prompts are as follows:

2020-04-17 11 dmserver startup failed 3515 FATAL [FATAL] database P0000014440 T00000000000014880 dmserver startup failed, code =-803 [Invalid ini config value]

2020-04-17 11 nsvr_ini_file_read failed 3515 FATAL [FATAL] database P0000014440 T00000000000014880 nsvr_ini_file_read failed, [code:-803]

Treatment method:

Comment out the ARCH_WAIT_APPLY parameter in the archive parameter file generated after configuring the archive log, or change the value of this parameter to 0 or 1, and then restart the service to start normally.

Attached: configuration information of Dameng archived parameter file

# DaMeng Database Archive Configuration file

# this is comments

# ARCH_WAIT_APPLY = 255

[ARCHIVE_LOCAL1]

ARCH_TYPE = LOCAL

ARCH_DEST = E:\ dmdbms\ data\ arc

ARCH_FILE_SIZE = 128,

ARCH_SPACE_LIMIT = 0