Enter analog in the basic window and press F1 to enter the analog editing window. Press F1 again to return to the command state.

Enter:

Test powered analog

Power pins XXX;XXX;XXX

Nonanalog pins YYY;YYY

Test "name NNN"

End test

3. Start writing subroutines:

Subtest "NNN"

Connect i to pins X

Connect l to pins Y

Connect s to pins Z

Connect g to ground

Connect rvca to pins X

Detector dcv expect X (corresponding to foot I)

Measure Xbox 1.5 and Xbox 0.95 (range of voltage measurements)

Source dcv,amX,icoX,on (signal source s)

Auxiliary dcv,amX,icoX (auxiliary source l)

Detector frequency, ecpect X (frequency rvca)

Measure X-ray 1.5 (frequency measurement)

End subtest

4.save "path / PN"

Among them, l bus, g bus, and rvca are optional, and not all of them have to be used in the test program. This completes a basic analog test program.