Get the App
SLTechnology News&Howtos  ›  Internet Technology  › 

How to use keystrokes to realize Repeat function in orCAD

Shulou Source: shulou.com Published: 2022-06-02 05:53:46 10月03日 Update

How to use keystrokes in orCAD to achieve Repeat function, in view of this problem, this article introduces the corresponding analysis and solution in detail, hoping to help more partners who want to solve this problem to find a more simple and easy way.

1. Introduce the reasons

Under orCAD, especially in the case of "bus" and "neat connection", there are many lines that need to be stretched. If you use "pull wire one by one", it will take a lot of time. At this time, you can use the Repeat method provided by the system to realize fast cable pulling.

2. Example case 1-neat connection

Under orCAD, if two devices present a "neat connection", as shown in the following figure, you can use "stretch after assembly".

First, as shown in the following figure:

Then, splice:

orCAD下使用按键实现Repeat功能

Finally, stretch any one to the appropriate position, as follows:

As shown in the above figure, the "effective connection" of "20 finished lines" can be completed in an instant.

3. Example case 2-bus connection

Under orCAD, especially in the "bus" part, there are many problems.

Contains at least four attributes: "bus", "bus label", "bus entry", and "bus connection"

Examples are as follows:

orCAD下使用按键实现Repeat功能

As shown in the figure above: "1" is "bus"; "2" is "bus label"; "3" is "bus entrance"; "4" is "bus connection"

Step 1:

After deleting "bus connection", select "bus Portal" and press "Ctrl+ left mouse button" to drag down to automatically "copy bus Portal"

Then, press the "F4" key to realize "Repeat to place the bus entrance"

PS: you must make sure that the "bus entry" is "selected"

orCAD下使用按键实现Repeat功能

Step 2:

First, connect the first wire, as follows:

Then, press the "Ctrl+ left mouse button" to drag down to automatically "copy the bus cable":

orCAD下使用按键实现Repeat功能

Finally, press the "F4" key to realize "Repeat placing bus connection"

PS: you must make sure that the "bus connection" is "selected"

4. Special usage

The core content consists of three steps: first, "place the first one after"; then, use the "Ctrl+ left mouse button"; finally, cooperate with "F4" to achieve "Repeat"

It can realize "Repeat placement" for the combination of "network label + network connection" at the same time.

The end result is:

This is the answer to the question about how to use buttons to achieve Repeat function in orCAD. I hope the above content can be of some help to you. If you still have a lot of doubts to be solved, you can follow the industry information channel to learn more about it.

Tags: Bus entry tidiness question situation label mouse function button picture above content method more step status network if yes guarantee help answer Apple Docker Huawei Linux macOS MariaDB Microsoft MySQL NVidia OPPO Reno OPPO Reno MySQL vpn Shulou Tech Info Xiaomi