Shulou Source: shulou.com Published: 2022-06-03 07:58:24 09月21日 Update

The DELL PowerEdge T30 does not boot, the memory stick and CPU have been replaced, and the fault remains the same. The problem is the power supply and the motherboard. Press and hold the small black round button next to the power supply, the power indicator is always on, and the CPU fan rotates, indicating that the power supply is normal. Then observe the boot button, orange, regular beat, first flash twice, and then flash, call DELL after sales to confirm that it is a motherboard fault. Replace the motherboard and resolve the problem. If it flashes twice and then seven times, it is a memory failure. PS:T30, which judges hardware faults by flashing orange lights on the boot button, is also applicable to low-end workstations such as T3620 and all desktops.

Tags: Fault power supply motherboard button memory orange regularity problem low end memory stick desktop desktop circle workstation indicator indicator hardware fan black seven hits Apple Docker Huawei Linux macOS MariaDB Microsoft MySQL NVidia OPPO Reno Xiaomi MySQL macOS Huawei Shulou Information