AIX error "BFE4C025 P H sysplanar0 UNDETERMINED ERROR"
When checking the system, it was found that the system reported an error:
$errpt | head
BFE4C025 0529221011 P H sysplanar0 UNDETERMINED ERROR
Check the corresponding error number and find the following diagnostic information:
$errpt-aj BFE4C025
……
Diagnostic Analysis
Diagnostic Log sequence number: 31453
Resource tested: sysplanar0
Resource Description: System Planar
Location:
SRC=\'#\'"/ > Description: Memory subsystem including external cache Predictive
Error, general. Refer to the system service
Documentation for more information.
Additional Words: 2-030000F0 3-28EC0110 4-C13920FF 5-41000000
6-00811930 7-00000001 8-00A0008A 9-5600502A
Possible FRUs:
Priority: M FRU: 00P5773 S/N: YL1081315356 CCIN: 30D5
Location: U787B.001.DNW7118-P1-C9-C4)
……
Since it may be a memory problem, check the specific location:
$lscfg-pv | grep-p DIMM
Memory DIMM:
Product Specific. (RT) VINI
Flag Field.XXMS
System Info Specific. (YL)... U787B.001.DNW7118-P1-C9-C4
Customer Card ID Number.30D5
Serial Number.YL1081315356
Part Number.00P5773
FRU Number. 00P5773
Size....2048
Version.RS6K
Physical Location: U787B.001.DNW7118-P1-C9-C4
It is suspected that there are occasional problems with the matching of this group of memory after only a 2G memory has been replaced before. check the memory:
$lsattr-El mem0
Goodsize 32000 Amount of usable physical memory in Mbytes False
Size 32000 Total amount of physical memory in Mbytes Fasle
A set of memory has been replaced, which looks like ok, waiting for subsequent changes.